VARIABLES AND FUNCTIONS
Pressure, temperature, level, flow, status contacts and Modbus signals, depending on installed instruments. Power supply and link diagnostics depend on the selected hardware.
MRMS / SOLUTIONS
Modular remote station for process instrumentation.
Modular configuration
MRMS-01 integrates pressure, temperature, level, flow and equipment-status measurements. Its architecture combines signal acquisition, data logging, communications and power to monitor process points, water networks and distributed equipment.
Isolated stations, camps, distributed infrastructure and monitoring points without permanent on-site staff.
Request a technical assessmentPressure, temperature, level, flow, status contacts and Modbus signals, depending on installed instruments. Power supply and link diagnostics depend on the selected hardware.
Preliminary reference configuration: 4 inputs at 4–20 mA, 4 digital inputs and 2 optional 0–10 V inputs using separate modules; isolated RS-485 and an industrial or embedded controller with a clock, watchdog and persistent storage. Ethernet, LTE or LoRa to a gateway are being considered according to site conditions.
Engineering defines ranges, units, signal compatibility, isolation, sampling and protection for each channel. A digital contact indicates a state; it does not replace a process measurement. Variables carry timestamps and data quality indicators to distinguish fresh readings from stale data.
Modular acquisition, persistent local logging and interchangeable communications. 12/24 V DC supply or a sized solar system; planned integration with MRMS Control for monitoring and alarms.
At a water pumping station, pressure and flow transmitters and running-status contacts supply data to the node. During a link outage, readings are intended to be stored locally and forwarded when communication resumes. The operator views trends and alarms; this first phase does not include remote pump commands.
Hypothetical example, with no attribution to actual installations or customers.The industrial ESP32-S3 is a prototype candidate, not an approved production selection; an industrial PLC or RTU are alternatives to assess. IP65 or higher is a design target subject to assembly verification, not an achieved certification. The final bill of materials, measured consumption, testing and definitive performance remain pending.
MAUMACH REMOTE SYSTEMS
Equipment and application images supplied by MAUMACH, visually enhanced with AI. Instrumentation and scope of supply depend on the agreed configuration.
























PRELIMINARY ARCHITECTURE
Instruments selected for the variable, fluid and environment.
Conditioned signals and modules defined by engineering.
Timestamped readings; recovery after outages subject to validation.
Ethernet, LTE or LoRa through a gateway according to site conditions.
Planned integration for historical data, diagnostics and alarms.
Proposed architecture: sensors → acquisition and protection → persistent logging → link → MRMS Control. LoRa requires a gateway and does not provide direct IP. MQTT/TLS is proposed where IP transport is available; QoS 1 can produce duplicates, so message identifiers and ingestion handling are planned. Physical and digital integration remain subject to prototyping and testing.
Discover MRMS ControlMRMS-01
No. The 4 inputs at 4–20 mA, 4 digital inputs and 2 optional 0–10 V inputs are a preliminary reference. Modules, isolation and the final channel count are defined by the instruments and project requirements.
Local logging and forwarding when the link recovers are proposed. Storage capacity, retention time and duplicate handling must be sized and tested; unlimited retention or loss-free operation are not guaranteed without validation.
No. The industrial ESP32-S3 is a laboratory candidate. The final selection may include an industrial PLC or RTU and requires validation of components, consumption, protection, enclosure and testing before commercial performance is defined.
MRMS-01 / MRMS-02 / MRMS-03
Three measurement approaches, one modular architecture.
Pressure, temperature, level, flow, status contacts and Modbus signals, depending on installed instruments. Power supply and link diagnostics depend on the selected hardware.
Modular configurationView product and applicationsTemperature and relative humidity, wind speed and direction; rainfall, atmospheric pressure and solar radiation according to selected instrumentation. Ranges and accuracy depend on the sensors selected and calibrated.
Modular configurationView product and applicationsContinuous level by radar, ultrasound or hydrostatic measurement according to fluid and geometry. Optional pressure and temperature; high or low level alarms, communication loss and out-of-range instrument signals.
Modular configurationView product and applicationsLET’S TALK
Let’s discuss your next industrial project or remote site.
Send an enquiry →